The
Model CP3230-OCl sensor is intended for measurement of free residual chlorine
(hypochlorous acid plus hypochlorite ion) in water.
l
飲水廠Measuring chlorine levels in drinking water.
l
加氯工藝Chlorine Adding control.
l
次氯酸鈉發(fā)生器Hypo chlorite measurement in electrolysis
generator
l
脫氯工藝Monitoring dechlorination processes.
The sensor requires no acid pretreatment and
can measure free chlorine in samples having pH as high as 9.5. The minimum
linear range of the sensor is 0 to 10 ppm about.
The CP3230-Cl2 is a membrane-covered amperometric sensor. The sensor
consists of a proprietary porous membrane stretched tightly over a platinum
cathode. A silver anode and an electrolyte solution complete the internal
circuit. During operation, free chlorine (hypochlorous acid plus hypochlorite
ion) diffuses from the sample through the membrane. A polarizing voltage
applied to the cathode completely reduces free chlorine to chloride ion. The
reduction produces a current between the cathode and the anode, which the
analyzer measures. The current is directly proportional to the rate at which
free chlorine diffuses through the membrane, which is ultimately proportional
to the concentration of free chlorine in the sample.
Instrument to measure sodium hypochlorite:
在線連續(xù)檢測變送器
TBD5-CPT3230-OCL transducer is designed for
on-line application;
Refer to http://www.fullsense.com/Products/BD3000/CPT3200/CPT3200IntC.pdf
手持式分析器
H-BD5w-Ocl is portable for laboratory or at
field smart analysis.
Refer to
http://www.fullsense.com/Products/Liquid/Water/Portable/HBD5WMSIntC.pdf
For more information,
please contact us: engineer@fullsense.com